This post contains important steps to create a VSAN-volume in a cluster. The list does not claim to be comprehensive.
- FW Update Server – especially SSD (this is most often a good idea!)
- Configure Array Controller (in this case P420i; FW-Version: v5.42)
- if necessary, configure a boot Array/logical drive
for each disk contribute taking part of an disk group create an array and a log. drive of level raid0 works fine with current firmware, because its just one task (“create array with raid 0”) to create all arrays/drives at once! - disable cache for every raid 0 drive
drive is to configure in Cache Manager by deselect all raid0-drives
- if necessary, configure a boot Array/logical drive
- Configuration network
- separate VLAN
- if possible use dedicated infrastructure
- NIC Teaming: active/passive or Link aggregation
just a few ports available: consider a vSwitch for VSAN and vMotion with active/standby vice versa - configure vmkernel-port and enable VSAN traffic on that port
- Edit/create Cluster
- enable VSAN feature (manual or automatic)
- if manual, claim disks
- check storage providers on vCenter level; 1 provider should be online, the rest should be in standby.
- assign license
- Create VM Storage Policies
- select vendor VSAN and define the rules you need
- the matching datastores are just the datastores, that can understand the policy. it does´t mean, they meet the requirements!
- Check after creation
- after the store is built and VMs allocating space from that volume, check the distributed objects.